      This issue relates to the following test suite run: https://testing.hpdd.intel.com/test_sets/091de072-4746-11e8-960d-52540065bddc

      test_60ab failed with the following error:

      'bad value: '
      

      env

      server: 2.10.3

      client: master tag-2.11.51

      test log

      == sanity test 60ab: llog_print params output values from set_param -P =============================== 22:22:19 (1524435739)
      CMD: trevis-12vm12 /usr/sbin/lctl get_param jobid_name
      CMD: trevis-12vm12 /usr/sbin/lctl set_param -P jobid_name=testname
      CMD: trevis-12vm12 /usr/sbin/lctl --device MGS llog_print params
      trevis-12vm12: OBD_IOC_LLOG_PRINT failed: Inappropriate ioctl for device
      CMD: trevis-12vm12 /usr/sbin/lctl set_param -P jobid_name=
      /usr/lib64/lustre/tests/sanity.sh: line 6223: [: =: unary operator expected
       sanity test_60ab: @@@@@@ FAIL: bad value:  
      

      VVVVVVV DO NOT REMOVE LINES BELOW, Added by Maloo for auto-association VVVVVVV
      sanity test_60ab - 'bad value: '

      Attachments

        Issue Links

          Activity

            [LU-10977] Interop 2.10.3 <-> master sanity test_60ab: Inappropriate ioctl for device
            pjones Peter Jones made changes -
            Fix Version/s New: Lustre 2.12.0 [ 13495 ]
            Resolution New: Fixed [ 1 ]
            Status Original: Open [ 1 ] New: Resolved [ 5 ]
            jamesanunez James Nunez (Inactive) made changes -
            Assignee Original: WC Triage [ wc-triage ] New: Saurabh Tandan [ standan ]
            sarah Sarah Liu made changes -
            Remote Link New: This issue links to "Page (HPDD Community Wiki)" [ 22760 ]
            sarah Sarah Liu made changes -
            Affects Version/s New: Lustre 2.12.0 [ 13495 ]
            sarah Sarah Liu made changes -
            Description Original: This issue was created by maloo for sarah_lw <wei3.liu@intel.com>

            This issue relates to the following test suite run: https://testing.hpdd.intel.com/test_sets/091de072-4746-11e8-960d-52540065bddc

            test_60ab failed with the following error:
            {noformat}
            'bad value: '
            {noformat}

            test log
            {noformat}
            == sanity test 60ab: llog_print params output values from set_param -P =============================== 22:22:19 (1524435739)
            CMD: trevis-12vm12 /usr/sbin/lctl get_param jobid_name
            CMD: trevis-12vm12 /usr/sbin/lctl set_param -P jobid_name=testname
            CMD: trevis-12vm12 /usr/sbin/lctl --device MGS llog_print params
            trevis-12vm12: OBD_IOC_LLOG_PRINT failed: Inappropriate ioctl for device
            CMD: trevis-12vm12 /usr/sbin/lctl set_param -P jobid_name=
            /usr/lib64/lustre/tests/sanity.sh: line 6223: [: =: unary operator expected
             sanity test_60ab: @@@@@@ FAIL: bad value:
            {noformat}





            VVVVVVV DO NOT REMOVE LINES BELOW, Added by Maloo for auto-association VVVVVVV
            sanity test_60ab - 'bad value: '
            New: This issue was created by maloo for sarah_lw <wei3.liu@intel.com>

            This issue relates to the following test suite run: [https://testing.hpdd.intel.com/test_sets/091de072-4746-11e8-960d-52540065bddc]

            test_60ab failed with the following error:
            {noformat}
            'bad value: '
            {noformat}
            env

            server: 2.10.3

            client: master tag-2.11.51

            test log
            {noformat}
            == sanity test 60ab: llog_print params output values from set_param -P =============================== 22:22:19 (1524435739)
            CMD: trevis-12vm12 /usr/sbin/lctl get_param jobid_name
            CMD: trevis-12vm12 /usr/sbin/lctl set_param -P jobid_name=testname
            CMD: trevis-12vm12 /usr/sbin/lctl --device MGS llog_print params
            trevis-12vm12: OBD_IOC_LLOG_PRINT failed: Inappropriate ioctl for device
            CMD: trevis-12vm12 /usr/sbin/lctl set_param -P jobid_name=
            /usr/lib64/lustre/tests/sanity.sh: line 6223: [: =: unary operator expected
             sanity test_60ab: @@@@@@ FAIL: bad value:
            {noformat}