[LU-11447] How to isolate a target's RPCs to a specific NID? Created: 28/Sep/18  Updated: 14/Apr/21  Resolved: 18/Dec/18

Status: Resolved
Project: Lustre
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Question/Request Priority: Minor
Reporter: Mahmoud Hanafi Assignee: Sonia Sharma (Inactive)
Resolution: Fixed Votes: 0
Labels: None

Attachments: PDF File netconfig.pdf    
Rank (Obsolete): 9223372036854775807

 Description   

See attached diag. netconfig.pdf

on a luster server that is running an MDT and OST targets. And if it has 2 NIDs on the same lnet network. Is there a way to isolate all MDT RPCs to ib0 and all OST RPCs to ib1?

 

The clients will only have a single interface.

 



 Comments   
Comment by Peter Jones [ 30/Sep/18 ]

Sonia

Could you please advise?

Peter

Comment by Sonia Sharma (Inactive) [ 01/Oct/18 ]

Hi Mahmoud,

Currently we don't have a way to select the IB network based on the server we want to send to. But with UDSP feature we will have this ability.

Comment by Mahmoud Hanafi [ 18/Dec/18 ]

This can be closed.

Comment by Peter Jones [ 18/Dec/18 ]

ok - thanks