[LU-12817] lnet: module parameters are not set correctly Created: 27/Sep/19  Updated: 16/Oct/20  Resolved: 15/Jan/20

Status: Resolved
Project: Lustre
Component/s: None
Affects Version/s: None
Fix Version/s: None

Type: Task Priority: Minor
Reporter: Amir Shehata (Inactive) Assignee: Amir Shehata (Inactive)
Resolution: Duplicate Votes: 0
Labels: None

Issue Links:
Related
is related to LU-11816 LNet Health: Correct timeout defaults Resolved
is related to LU-12772 bulk timeout after 2.12.2 clients upg... Closed
Rank (Obsolete): 9223372036854775807

 Description   

Module parameters (ex: lnet_transaction_timeout) is not being set correctly when using the module parameter file /etc/modparam.d/<>.conf.

This has been observed by NASA in LU-12772



 Comments   
Comment by Serguei Smirnov [ 12/Oct/19 ]

The issue with the parameters not being set as specified in the configuration file has been fixed by the following commit:

113f39aa9b2381be9af4b50c1aad4268b0683507 LU-11816 lnet: setup health timeout defaults

Comment by Andreas Dilger [ 15/Jan/20 ]

Close as a duplicate of LU-11816.