[LU-1551] FYI: Contollers on storage1 and storage 2 have both crashed at University of Delaware Created: 21/Jun/12  Updated: 04/Sep/12  Resolved: 04/Sep/12

Status: Resolved
Project: Lustre
Component/s: None
Affects Version/s: Lustre 2.0.0, Lustre 1.8.6
Fix Version/s: None

Type: Bug Priority: Major
Reporter: Archie Dizon Assignee: Cliff White (Inactive)
Resolution: Fixed Votes: 0
Labels: None
Environment:

Clustering


Severity: 1
Rank (Obsolete): 6377

 Description   

Are there a known issues with Wham cloud configuration that would cause RAID controllers to fail. It seems that the customer has encountered two failures on two separate storage systems. We are currently working with U Del to determine if this issue is hardware vs software related failure.



 Comments   
Comment by Cliff White (Inactive) [ 21/Jun/12 ]

There are no issues with Lustre that should cause a storage controller to fail. However Lustre does generate a high volume of IO and we have seen some instances in the past where hardware has struggled to keep up.

Comment by Cliff White (Inactive) [ 27/Jun/12 ]

What is your current state?

Comment by Cliff White (Inactive) [ 09/Jul/12 ]

Can we close this issue, or is there something more we can do for you?

Comment by Cliff White (Inactive) [ 04/Sep/12 ]

Closing - please reopen if you have further data or questions

Generated at Sat Feb 10 01:17:38 UTC 2024 using Jira 9.4.14#940014-sha1:734e6822bbf0d45eff9af51f82432957f73aa32c.