Description
This issue was created by maloo for Lai Siyao <lai.siyao@intel.com>
This issue relates to the following test suite run: https://testing.hpdd.intel.com/test_sets/2a1994c4-bac4-11e7-9abd-52540065bddc.
The sub-test test_24v failed with the following error:
After checking the code, this looks to be caused by statahead code, during directory removal statahead should be turned off, but actually it's not, I'll cook a fix soon.
Please provide additional information about the failure here.
Info required for matching: sanity 24v
Attachments
Issue Links
- is duplicated by
-
LU-10195 sanity test_24v: timeout occurred after 71 mins
- Resolved