Details
-
Bug
-
Resolution: Fixed
-
Critical
-
None
-
None
-
3
-
9223372036854775807
Description
The server highest transno can be lost after second-in-row failover due to uninitialized in-memory parameter lcd_last_transno
Oleg Drokin (green@whamcloud.com) merged in patch https://review.whamcloud.com/37187/
Subject:
LU-13087target: init lcd last transno from reply dataProject: fs/lustre-release
Branch: b2_12
Current Patch Set:
Commit: ae616d1b79cabccecaac74f84f9d614b0013f6d6