Uploaded image for project: 'Lustre'
  1. Lustre
  2. LU-14924

LustreError: 133-1: nbp17-OST0064-osc-ffff9bf24bc99800: BAD READ CHECKSUM

    XMLWordPrintable

Details

    • Bug
    • Resolution: Fixed
    • Minor
    • Lustre 2.15.0
    • None
    • None
    • 3
    • 9223372036854775807

    Description

      when we verify and feed the T10 GRD tag to lnb, we could use the wrong lnb

      if page 2 is mapped to hole and the block mapped for the page 3 is contiguous with the page 1,

      on bio level the blocks are all contiguous but we will pick up page 2's lnb for page 3

      Attachments

        Issue Links

          Activity

            People

              dongyang Dongyang Li
              dongyang Dongyang Li
              Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: