Uploaded image for project: 'Lustre'
  1. Lustre
  2. LU-18676

sanity-quota test_49: block usage for user ID 10 is wrong 0, 2

Details

    • Bug
    • Resolution: Unresolved
    • Major
    • None
    • Lustre 2.16.1
    • 3
    • 9223372036854775807

    Description

      This issue was created by maloo for Andreas Dilger <adilger@whamcloud.com>

      This issue relates to the following test suite run:
      https://testing.whamcloud.com/test_sets/8f73fd31-5306-453d-b487-920bca8adb5b
      https://testing.whamcloud.com/test_sets/218e8071-62c6-4592-8436-2ad404d43736

      test_49 failed with the following error:

      block usage for user ID 10 is wrong 0, 2
      

      Test session details:
      clients: https://build.whamcloud.com/job/lustre-reviews/109554 - 5.14.0-503.15.1.el9_5.x86_64
      servers: https://build.whamcloud.com/job/lustre-reviews/109554 - 5.14.0-503.15.1_lustre.el9.x86_64

      Have seen this failure intermittently since 2024-12-10, but has started failing a lot since 2025-01-21 on master (10x or more per day) during review testing.

      The test output doesn't show the UID so it is hard to see what is going on with the test. It might be that the file writes are taking longer than expected to commit to storage so the block count is not updated? However, none of the other IDs are reporting an error. It might be that they are all wrong, and this is just the first one checked and then the test exits?

      VVVVVVV DO NOT REMOVE LINES BELOW, Added by Maloo for auto-association VVVVVVV
      sanity-quota test_49 - block usage for user ID 10 is wrong 0, 2

      Attachments

        Issue Links

          Activity

            People

              hongchao.zhang Hongchao Zhang
              maloo Maloo
              Votes:
              0 Vote for this issue
              Watchers:
              5 Start watching this issue

              Dates

                Created:
                Updated: