Description
It should be noted that this sequence is only critical during the first (initial) startup. After that it doesn't matter so much because all services have correctly registered and have been cataloged.
Hi Yes,
Thanks for finding this Alex. The manual should be updated with the
correct order.
-cf
On 03/07/2013 09:39 AM, Alex Kulyavtsev wrote:
> Hi Colin.
> This is not what the manual says.
>
> Shall it be corrected then? Or, add description for startup sequence
> in different situations (first start, restart).
>
> The manual (or online information) does not describe graceful shutdown
> sequence for separate MGS/MDT configuration, it will be nice to add
> that too.
>
> Alex.
>
> E.g.
>
> http://wiki.lustre.org/manual/LustreManual20_HTML/LustreOperations.html#5
> 0438194_24122
> and similar
>
> http://build.whamcloud.com/job/lustre-manual/lastSuccessfulBuild/artifact
> /lustre_manual.xhtml#dbdoclet.50438194_24122